8787

Audio, Control and Instrumentation, 8 Conductor 24 AWG, Shielded Quads; 2 Conductor 22 AWG Unshielded

...
8 Conductor 24 AWG stranded (7x32) TC, shielded quads, polyethylene insulation, 24 AWG stranded TC drain wire; 2 Conductor 22 AWG stranded (7x30) TC , Unshielded, PVC insulation, PVC jacket.
Get Product Alerts
Specifications
Product Overview

Suitable Applications

low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line level audio; computer communication; panel wiring

Physical Characteristics (Overall)
Conductor
AWG Stranding Material No. of Conductors
24 7x32 TC - Tinned Copper 8
22 TC - Tinned Copper 2

Conductor Count

10

Insulation
Material Nominal Wall Thickness
PE - Polyethylene 0.012 in
PVC - Polyvinyl Chloride 0.015 in
Color Chart
Number Color
1 Red Quad
2 White
3 Green Quad
4 Blue
Color Chart 2
Color
Gray, White, Blue, Green
Red Beldfoil®
Brown, Red, Yellow, Orange
Green Beldfoil®
White, Blue
Unshielded
Inner Shield Material
Type Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG Drainwire Construction n x D
Tape Bi-Laminate (Alum+Poly) Beldfoil® (Z-Fold®) 100% TC - Tinned Copper 24 7x32
Tape Bi-Laminate (Alum+Poly) Beldfoil® 100% TC - Tinned Copper
Tape Bi-Laminate (Alum+Poly) Beldfoil® 100%

Table Notes

Gray, White, Blue, Green; Brown, Red, Yellow, Orange; White, Blue

Outer Shield Material
Material
No Shield
Outer Jacket Material
Material Nominal Diameter Nominal Wall Thickness
PVC - Polyvinyl Chloride 0.29 in 0.03 in
Electrical Characteristics
Conductor DCR
Element Nominal Conductor DCR Nominal Inner Shield DCR
24 AWG 23.9 Ohm/1000ft 5 Ohm/1000ft
15 Ohm/1000ft
Current
Max. Recommended Current [A]
1.5 Amps per Conductor at 25°C (24 AWG); 2.0 Amps per Conductor at 25°C (22 AWG)
Voltage
Non-UL Voltage Rating
350 V RMS
Temperature Range

Non-UL Temp Rating

80°C

Operating Temp Range

-20°C To +80°C

Mechanical Characteristics

Bulk Cable Weight

45 lbs/1000ft

Max. Pull Tension

62.2 lbs

Min Bend Radius/Minor Axis

3 in

Standards

CPR Euroclass

Eca

Applicable Environmental and Other Programs

Environmental Space

Indoor (Not Riser or Plenum)

EU Directive 2000/53/EC (ELV)

Yes

EU Directive 2003/96/EC (BFR)

Yes

EU Directive 2011/65/EU (RoHS 2)

Yes

EU Directive 2012/19/EU (WEEE)

Yes

EU Directive 2015/863/EU (RoHS 2 amendment)

Yes

EU Directive Compliance

EU Directive 2003/11/EC (BFR)

EU CE Mark

Yes

EU RoHS Compliance Date (yyyy-mm-dd)

2005-04-01

MII Order #39 (China RoHS)

Yes

Suitability

Suitability - Indoor

Yes

Flammability, LS0H, Toxicity Testing

UL Flammability

VW-1, UL1685 UL Loading

IEC Flammability

IEC 60332-1-2

Plenum/Non-Plenum

Plenum (Y/N)

No

Footnote

C - CRATE REEL PUT-UP.

Product Notes

Notes

Inner Beldfoil« shield over 24 AWG quads. Each quad wrapped in transparent polyester tape. Red Beldfoil« shield over one quad, Green Beldfoil« shield over the other. (2) quads and (2) unshielded conductors cabled.

History

Update and Revision

Revision Number: 0.275 Revision Date: 03-16-2021

Part Numbers
Item # Color Putup Type Length UPC
8787 060500 Chrome Reel 500 ft 612825216391
8787 060U500 Chrome UnReel 500 ft 612825216414