Product Number: 50106ASFR
BELDEN Industrial Ethernet CAT6A cable, S/FTP, LSZH, Anti Rodent, Anti Termite, 4 Pair, AWG 23,Indoor
BELDEN Industrial Ethernet CAT6A, S/FTP, 4x2x 23AWG, Solid Bare Copper Conductors, Foam Polyolefin Insulation, Individually foil shielded pairs & Overall tinned copper braid shield, LSZH Jacket, Anti Rodent & Anti Termite cable.
-
Availability:
-
Global inventory:
Specifications
Product Overview
Suitable Applications |
Ethernet: 10GBase-T, 100Base-TX, 1000Base-T |
---|
Construction Details
Conductor
Element | Size | Stranding Class | Material |
---|---|---|---|
Pair(s) | 23 AWG | Class 1 | BC - Bare Copper |
Insulation
Material | Nom. Insulation Diameter | Color Code |
---|---|---|
PO - Polyolefin (Foam) | 1.35 mm (0.0531 in) | White, Blue, Orange, Green, Brown |
Inner Shield
Element | Shield Type | Material |
---|---|---|
Pair(s) | Tapes (Each Pair) | Bi-Laminate (Alum+Poly) |
Outer Shield
Shield Type | Material | Coverage |
---|---|---|
Braid | Tinned Copper (TC) | 30% |
Outer Jacket
Material | Ripcord |
---|---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | Yes |
Overall Cable Diameter (Nominal) |
7.8 ± 0.3 mm |
---|
Electrical Characteristics
Electricals
Max. Conductor DCR | Nom. Characteristic Impedance |
---|---|
95 Ω/km @ 20°C | 100 Ohm |
Table Notes |
Nominal Velocity of Propagation: 0.77 |
---|
High Frequency
Frequency | Max. Insertion Loss (Attenuation) [dB/100m] | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Min. PSANEXT [dB] | Min. PSAACRF [dB] | Min. TCL [dB] | Min. ELTCTL [dB] | Min. Coupling Attenuation [dB] |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 2.1 | 75.3 | 72.3 | 73.2 | 70.2 | 68 | 65 | 20 | 67 | 67 | 40 | 35 | |
4 MHz | 3.8 | 66.3 | 63.3 | 62.5 | 59.5 | 56 | 53 | 23 | 67 | 66.2 | 34 | 23 | |
10 MHz | 5.9 | 60.3 | 57.3 | 54.4 | 51.4 | 48 | 45 | 25 | 67 | 58.2 | 30 | 15 | |
16 MHz | 7.5 | 57.2 | 54.2 | 49.7 | 46.7 | 43.9 | 40.9 | 25 | 67 | 54.1 | 28 | 10.9 | |
31.3 MHz | 10.5 | 52.9 | 49.9 | 42.4 | 39.4 | 38.1 | 35.1 | 23.6 | 67 | 48.3 | 25.1 | 5.1 | 55 |
62.5 MHz | 15 | 48.4 | 45.4 | 33.4 | 30.4 | 32.1 | 29.1 | 21.5 | 65.6 | 42.3 | 22 | 55 | |
100 MHz | 19.1 | 45.3 | 42.3 | 26.2 | 23.2 | 28 | 25 | 20.1 | 62.5 | 38.2 | 20 | 55 | |
125 MHz | 21.5 | 43.8 | 40.8 | 22.3 | 19.3 | 26.1 | 23.1 | 19.4 | 61 | 36.3 | 19 | 53 | |
200 MHz | 27.6 | 40.8 | 37.8 | 13.2 | 10.2 | 22 | 19 | 18 | 58 | 32.2 | 17 | 49 | |
250 MHz | 31.1 | 39.3 | 36.3 | 8.2 | 5.2 | 20 | 17 | 17.3 | 56.5 | 30.2 | 16 | 47 | |
350 MHz | 37.3 | 37.1 | 34.1 | 17.1 | 14.1 | 17.3 | 54.3 | 27.3 | 44 | ||||
500 MHz | 45.3 | 34.8 | 31.8 | 14 | 11 | 17.3 | 52 | 24.2 | 41 |
Transfer Impedance
Frequency | Max. Transfer Impedance |
---|---|
1 | 50 |
10 | 100 |
30 | 200 |
100 | 1000 |
Voltage
Voltage Rating | Breakdown Voltage |
---|---|
72 V DC | 2500V DC/2Sec. |
Mechanical Characteristics
Temperature
Operating | Storage |
---|---|
-30°C to + 60°C | -20°C to + 50°C |
Bend Radius
Installation Min. |
---|
62.4 mm (2.46 in) |
Bulk Cable Weight |
67 kg/km (45 lbs/1000ft) |
---|
Standards and Compliance
Environmental Suitability |
Indoor |
---|---|
Flammability / Reaction to Fire |
IEC 60332-1-2, IEC 60332-3-22 |
IEEE Compliance |
IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
Data Category |
Category 6A |
TIA/EIA Compliance |
ANSI/TIA 568.2-D |
ISO/IEC Compliance |
ISO/IEC 11801 Ed. 2.0:2002/A2:2010/C1:2011 |
European Halogen Free Standards |
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 µS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 |
European Directive Compliance |
EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2) |
APAC Compliance |
China RoHS II (GB/T 26572-2011) |
History
Update and Revision |
Revision Number: 0.13 Revision Date: 04-29-2024 |
---|
Belden.GenericSpecificationTitle
Update and Revision |
Revision Number: 0.13 Revision Date: 04-29-2024 |
---|