Product Number: 2233RW

Indoor/Outdoor Stadium Cable, RG-11/U Triax, 14 AWG solid, CMR

RG-11/U Triax, 14 AWG solid .064" bare copper conductor, gas-injected foam HDPE insulation, bare copper double shields (95% and 80% coverage), PVC insulation between braids, water blocking tape, CPE jacket, CMR rated

  • Availability:
    Global
  • Status:
    Active

Specifications

Suitable Applications

Analog audio, burial, Sports Stadium

RG Type

11

Conductor

Size Stranding Nom. Diameter Material
14 Solid 0.064 in BC - Bare Copper

Insulation

Material Nom. Insulation Diameter
PE - Polyethylene (Foam) 0.285 in (7.24 mm)

Insulation Table Notes

Gas Injected

Inner Shield

Shield Type Material Coverage
Braid Bare Copper (BC) 95%

Inner Jacket

Material Nom. Diameter
PVC - Polyvinyl Chloride 0.365 in (9.27 mm)

Outer Shield

Outer Shield Type Material Coverage
Braid Bare Copper (BC) 80%

Outer Jacket

Material Nom. Diameter
CPE - Chlorinated Polyethylene 0.475 in

Return Loss

Frequency Min. Return Loss
5 - 850 MHz 21 dB
850 - 4500 MHz 15 dB

Attenuation

Frequency Nom. Attenuation
1.0 MHz 0.14 dB/100ft
3.6 MHz 0.3 dB/100ft
10 MHz 0.4 dB/100ft
71.5 MHz 1.1 dB/100ft
135 MHz 1.6 dB/100ft
270 MHz 2.3 dB/100ft
360 MHz 2.6 dB/100ft
540 MHz 3.3 dB/100ft
720 MHz 3.8 dB/100ft
750 MHz 4.0 dB/100ft
1000 MHz 4.6 dB/100ft
1500 MHz 5.9 dB/100ft
2250 MHz 7.4 dB/100ft
3000 MHz 9 dB/100ft
4500 MHz 12.5 dB/100ft

Electricals

Nom. Conductor DCR Nom. Inner Shield DCR Nom. Outer Shield DCR Nom. Capacitance Cond-to-Shield Nom. Characteristic Impedance Nom. Velocity of Prop.
2.6 Ohm/1000ft (8.5 Ohm/km) 1.7 Ohm/1000ft (5.6 Ohm/km) 1.5 Ohm/1000ft (4.9 Ohm/km) 16.1 pF/ft (52.8 pF/m) 75 Ohm 84%

Voltage

UL Voltage Rating
300 V RMS

Temperature

UL Temperature Operating
75°C -30°C To +75°C

Max. Pull Tension

170 lbs (77 kg)

Bulk Cable Weight

125 lbs/1000ft (186 kg/km)

Environmental Suitability

Indoor/Outdoor, Indoor, Aerial - Black only, When supported by messenger wire

Flammability / Reaction to Fire

UL1666 Vertical Shaft

CPR Compliance

CPR Euroclass: Eca

NEC / UL Compliance

CMR

European Directive Compliance

EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)

UK Regulation Compliance

UKCA Mark

APAC Compliance

China RoHS II (GB/T 26572-2011)

Notes

Water blocking tape between outer jacket and outer braid. Print legend includes sequential footage marks.

Update and Revision

Revision Number: 0.257 Revision Date: 09-07-2025

Footnote

C - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.

Update and Revision

Revision Number: 0.257 Revision Date: 09-07-2025

Footnote

C - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.


Part Numbers

Item # Color Putup Type Length UPC Footnote
2233RW 0101000 Black Reel 1,000 ft 612825384670
2233RW 0104000 Black Reel 4,000 ft 612825384687 C Z

Resources

Resources