52C0.14YY

MachFlex™ LiYY, 52 C 0.14mm² Str BC, PVC Ins, PVC Jkt

...
MachFlex™ LiYY PVC Control VDE Certified & Signal Cables, 52 Conductor 0.14mm² Stranded Bare Copper, PVC Insulation, PVC Jacket
Get Product Alerts
Specifications
Product Overview

Suitable Applications

Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, pressure gauge, temperature controllers, control panels, vibration monitoring systems, intelligentsecurity controllers, production machinery and many more

Physical Characteristics (Overall)
Conductor
Element AWG Stranding Material No. of Conductors
Conductor(s) 0.14 mm² Stranded BC - Bare Copper 52

Conductor Count

52

Insulation
Material
PVC - Polyvinyl Chloride
Color Chart
Number Color
1 White
2 Brown
3 Green
4 Yellow
5 Grey
6 Pink
7 Blue
8 Red
9 Black
10 Violet
11 Gray with Pink strips
12 Red with Blue strips
13 White with Green strips
14 Brown with Green strips
15 White with Yellow strips
16 Yellow with Brown strip
17 White with Gray strips
18 Gray with Brown strips
19 White with Pink strips
20 Pink with Brown strips
21 White with Blue strips
22 Brown with Blue strips
23 White with Red strips
24 Brown with red strips
25 White with Black strips
26 Brown with Black strips
27 Grey with Green strips
28 Yellow with Gray strips
29 Pink with Green strips
30 Yellow with Pink strips
31 Green with Blue strips
32 Yellow with Blue strips
33 Green with Red strips
34 Yellow with Red strips
35 Green with Black strips
36 Yellow with Black strips
37 Gray with Blue strips
38 Pink with Blue strips
39 Gray with Red strips
40 Pink with Red strips
41 Gray with Black strips
42 Pink with Black strips
43 Blue with Black strips
44 Red with Black strips
45 White with 2 Brown strips
46 Yellow with 2 Green strips
47 Gray with 2 Pink strips
48 Red with 2 Blue strips
49 White with 2 Green strips
50 Brown with 2 Green strips
51 White with 2 Yellow strips
Yellow with 2 Brown strips
Outer Jacket
Material Nominal Diameter
PVC - Polyvinyl Chloride 10.6 mm
Electrical Characteristics
Conductor DCR
Max. Conductor DCR
138 Ohm/km
Capacitance
Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Shield
120 pF/m 160 pF/m

Insulation Resistance

20 GOhm x cm

Min Insulation Resistance

20 GOhm x cm

Inductance
Nominal Inductance
0.5 µH/m
Voltage
Description Voltage Rating [V]
Operating Voltage 350 V
Testing Voltage 1200 V
Temperature Range

Installation Temp Range

-40°C to +80°C

Operating Temp Range

-5°C to +70°C

Mechanical Characteristics

UV Resistance

Yes

Bulk Cable Weight

160 kg/km

Min. Bend Radius During Installation

4 x OD

Min. Bend Radius During Operation

10 x OD

Standards

Other Specification

IEC 60228, DIN EN 50290‐2‐22, VDE 0812, DIN VDE 0207‐363‐4‐1, DIN 47100, DIN VDE 0295, BS 6360

Suitability

Suitability - Indoor

Yes

Suitability - Outdoor

Yes

Suitability - Sunlight Resistance

Yes

Flammability, LS0H, Toxicity Testing

IEC Flammability

IEC 60332-1-2

Other Flammability

DIN VDE 0482-332-1-2, DIN EN 60332-1-2

History

Update and Revision

Revision Number: 0.12 Revision Date: 08-27-2021

Part Numbers
Item # Color Length
52C0.14YY 010200M Black, RAL 9005 200 m
52C0.14YY 010305M Black, RAL 9005 305 m
52C0.14YY F2V200M Gray, RAL 7032 200 m