28339AS

TC VN/PVC, 5 C #16 Str BC, PVC-NYL Ins E2, OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry/Wet SUN RES DIR BUR

28339AS
UL Type TC (1277) PVC-Nylon/PVC, 5 Conductor 16AWG (7x24) Bare Copper, PVC-NYL Insulation E2 Color Code, Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC-ER 150V NPLF 90C Dry/Wet SUN RES DIR BUR
Get Product Alerts
Specifications

Put-Up Type

Reel

Physical Characteristics (Overall)
Conductor
Element AWG Stranding Material Nominal Diameter No. of Conductors
Conductor(s) 16 7x24 BC - Bare Copper 0.057 in 5

Conductor Count

5

Insulation
Material Nominal Diameter Nominal Wall Thickness
PVC/Nylon - Polyvinyl Chloride + Nylon 0.101 in 0.024 in
Color Chart
Number Color
1 Black
2 Red
3 Blue
4 Orange
5 Yellow
Outer Shield
Type Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG
Tape Bi-Laminate (Alum+Poly) Beldfoil® 100% TC - Tinned Copper 16
Outer Jacket
Material Nominal Diameter Nominal Wall Thickness
PVC - Polyvinyl Chloride 0.366 in 0.047 in
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR
4.2 Ohm/1000ft
Current
Max. Recommended Current [A]
6.4 Amps per Conductor at 25ºC
Voltage
UL Description UL Voltage Rating Voltage Rating [V]
TC-ER 600 V RMS (Type TC) 600 V RMS (Type TC)
NPLF 150 V RMS (Type NPLF)
Temperature Range

UL Temp Rating

90°C Dry, 90°C Wet

Operating Temp Range

Wet/Dry: -30°C to 90°C

Wet Temp Range

-30°C To +90 °C

Dry Temp Range

-30°C To +90 °C

Mechanical Characteristics

Bulk Cable Weight

94 lbs/1000ft

Max. Pull Tension

175 lbs

Min. Bend Radius/Minor Axis

3.7 in

Standards

NEC/(UL) Compliance

NPLF, TC-ER, TFFN Singles

Other Specification

ICEA S-73-532, S-95-658, S-61-402

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV)

Yes

EU Directive 2003/11/EC (BFR)

Yes

EU Directive 2011/65/EU (RoHS 2)

Yes

EU Directive 2012/19/EU (WEEE)

Yes

EU Directive 2015/863/EU (RoHS 2 amendment)

Yes

EU Directive Compliance

EU Directive 2003/11/EC (BFR)

EU CE Mark

Yes

EU RoHS Compliance Date (yyyy-mm-dd)

2005-04-01

MII Order #39 (China RoHS)

Yes

Suitability

Suitability - Burial

Yes

Suitability - Indoor

Yes

Suitability - Outdoor

Yes

Suitability - Sunlight Resistance

Yes

Flammability, LS0H, Toxicity Testing

C(UL) Flammability

FT4

UL Flammability

UL1685 UL Loading

IEEE Flammability

1202

UL voltage rating

600 V RMS (Type TC)

Plenum/Non-Plenum

Plenum (Y/N)

No

Footnote

C - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.

History

Update and Revision

Revision Number: 0.159 Revision Date: 08-27-2021

Belden.PartNumbers
Item # Color Put-Up Type Length UPC
28339AS 0105000 Reel 612825136132
28339AS 0105000 Black Reel 5,000 ft 612825136132
28339AS01010000 Black Reel 10,000 ft 612825136149