3107T

RS485, 2 Pr #22 Str TC, PE Ins, OS+TC Brd, LSZH Jkt, CMG

...
RS-485, 2 Pair 22AWG (7x30) Tinned Copper, PE Insulation, Overall Beldfoil®+Tinned Copper Braid(65%) Shield, LSZH Outer Jacket, CMG, PLTC
Get Product Alerts
Specifications
Product Overview

Suitable Applications

harsh environment, IIoT, factory or process automation, video, audio, data communication, etc.

Construction Details
Conductor
Element Number of Element AWG Stranding Material
Pair(s) 2 22 7x30 TC - Tinned Copper
Insulation
Element Material Thickness Color Code Notes
Pair(s) PE - Polyethylene (Foam) 0.025 in White/Blue Stripe & Blue/White Stripe, White/Orange Stripe & Orange/White Stripe HDPE
Outer Shield Material
Shield Type Material Coverage Drainwire Type
Tape + Braid Bi-Laminate (Alum+Poly) + Tinned Copper (TC) 100% + 65% 22 AWG (7x30) TC
Outer Jacket Material
Material Thickness Nom. Diameter
LSZH - Low Smoke Zero Halogen (Flame Retardant) 0.125 in 0.494 in

Cable Diameter (Nominal)

0.494 in

Electrical Characteristics
Electricals
Element Characteristic Impedence Nom. Velocity of Prop.
Pair(s) 120 Ohm 78%
High Frequency (Nominal/Typical)
Element
Pair(s)
Voltage
UL Voltage Rating
300 V (CMG, PLTC)
Mechanical Characteristics
Temperature
UL Rating Operating
75°C -20°C to +75°C
Bend Radius
Stationary Min.
4.9 in

Max. Pull Tension

83 lbs

Bulk Cable Weight

125 lbs/1000ft

Standards and Compliance

Environmental Suitability

Sunlight Resistance

Flammability / Fire Resistance

UL1685 UL Loading, FT4

NEC / UL Compliance

Article 725, Article 800, CMG, PLTC

CEC / C(UL) Compliance

CMG

European Directive Compliance

EU CE Mark, EU Directive 2015/863/EU, EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE)

APAC Compliance

China RoHS II (GB/T 26572-2011)

History

Update and Revision

Revision Number: 0.132 Revision Date: 02-16-2021