29507

VFD 300% Gnd, 3C+G #2 Str TC, XLPE Ins+PVC Gnd, OS+TC Brd w/4-#8 TC Drains, Blk PVC Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC

...
Belden 300% Ground Flexible VFD, 3 Conductor 2AWG (7x19x23) Tinned Copper, XLPE Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil®+Tinned Copper Braid(85%) Shield w/4-8AWG Tinned Copper Drains, Black PVC Outer Jacket, 600/1000V TC-ER
Request Sample Get Product Alerts
Specifications

Put-Up Type

Reel

Product Overview

Suitable Applications

Variable Frequency Drives (VFD); AC Motor and Drive Systems

Construction Details
Conductor
Element Number of Element Size Stranding Material
Conductor(s) 3 2 AWG 7x19x23 TC - Tinned Copper
Ground 1 2 AWG 7x19x23 TC - Tinned Copper
Insulation
Element Material Nom. Thickness Color Code
Conductor(s) XLPE - Cross-Linked Polyethylene (Thermoset) 0.062 in (1.6 mm) Black and Numbered
Ground PVC - Polyvinyl Chloride 0.062 in (1.6 mm) Green/Yellow Stripe
Outer Shield
Shield Type Material Coverage
Tape Tri-Laminate (Alum+Poly+Alum) 100%
Braid Tinned Copper (TC) 85%
Outer Jacket
Material Nom. Thickness Nom. Diameter Ripcord
PVC - Polyvinyl Chloride 0.095 in (2.4 mm) 1.324 in (33.63 mm) Yes

Overall Cable Diameter (Nominal)

1.324 in (33.63 mm)

Electrical Characteristics
Electricals
Element Nom. Conductor DCR Nom. Capacitance Cond-to-Cond Nom. Capacitance Cond-to-Other (Conds + Shield) Nom. Characteristic Impedence Nom. Velocity of Prop. Max. Current
Conductor(s) 0.152 Ohm/1000ft (0.499 Ohm/km) 40 pF/ft (130 pF/m) 72 pF/ft (240 pF/m) 46 Ohm 55% 130 Amps per Conductor at 30ºC
Voltage
UL Voltage Rating
1000 V (TC, WTTC, UL Flexible Motor Supply Cable, CSA AWM I/II A/B), 600 V (C(UL) CIC TC)
Mechanical Characteristics
Temperature
UL Temperature Operating
90°C Dry, 90°C Wet -40°C To +90°C
Bend Radius
Stationary Min. Installation Min.
15.9 in (404 mm) 15.9 in (404 mm)

Max. Pull Tension

3327 lbs (1509 kg)

Bulk Cable Weight

1546 lbs/1000ft (2301 kg/km)

Standards and Compliance

Environmental Suitability

Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial

Sustainability

CA Prop 65

Flammability / Reaction to Fire

UL1685 UL Loading, FT4, FT4, 1202, 383 Vertical Tray Flame Test (70,000 BTU)

NEC / UL Compliance

Article 336, TC-ER, WTTC, RHW-2, UL Flexible Motor Supply Cable

AWM Compliance

I/II A/B

CEC / C(UL) Compliance

CIC, TC

ICEA Compliance

S-95-658

European Directive Compliance

EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)

APAC Compliance

China RoHS II (GB/T 26572-2011)

Other Standard Compliance(s)

P-07-KA070003-MSHA

History

Update and Revision

Revision Number: 0.460 Revision Date: 12-15-2021

Part Numbers
Item # Color Putup Type Length UPC
29507 010250 Black Reel 250 ft 612825137368
29507 010500 Black Reel 500 ft 612825137375
29507 0101000 Black Reel 1,000 ft 612825137320
29507 0102000 Black Reel 2,000 ft 612825137351